36
< 3625 01 >

RAST 5 connectors, pitch 5.0 mm

RAST 5 connector for indirect mating, insulation displacement technology (IDT), with locking on tab, consecutive placement without loss of pitch

Approvals: VDE, cULus
Data Sheet (PDF)

Technical Data

Environmental conditions

Temperature range: -40 °C/+125 °C – 3625 01
-40 °C/+130 °C – 3625 01 M08
-40 °C/+130 °C – 3625 01 M20  *1

1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card

Materials

Insulating body: PA, V-2 according to UL94 – 3625 01
PA, V-2 according to UL94 – 3625 01 M08
PA, V-0 according to UL94 – 3625 01 M20  *1

Contact spring: CuSn, silver-plated

1) M08: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
M20: material halogen-free, GWFI 850 °C (0.4 mm), GWIT 775 °C (0.4 mm)

Mechanical data

Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244

Insertion force: ≤ 50 N  *1

Withdrawal force: ≥ 15 N  *2

1) measured with a polished flat steel pin, nominal thickness 0.8 mm

2) measured with a polished flat steel pin, nominal thickness 0.8 mm

Connectable conductors for IDT area

Construction: discrete conductor, notched flat cable 5.0 mm

Section min.: 0,75 mm²

Section max.: 1,5 mm²

Insulation diameter: ≤ 3,0 mm

Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.

Electrical data (at Tamb 20 °C)

Contact resistance: ≤ 5 mΩ

Rated current: 16 A (1.0–1.5 mm², Tamb 70 °C, VDE/ULus)
16 A (1.5 mm², Tamb 70 °C, cUL)
12 A (1.0 mm², Tamb 70 °C, cUL)

Rated voltage: 250 V AC (VDE/cULus)

Counterparts

Harnessing Equipment

Approved Cables

Connector systems with insulation displacement and crimp technology require suitable cables and accurate processing. In order to assure safe function of the connectors they must be processed with Lumberg harnessing equipment (series 97), according to Lumberg processing instructions, using cables approved by Lumberg. Do not hesitate to contact us if you have any questions!

The cables listed here have been tested in the laboratory and have been approved suitable for the specified connector type. Lumberg cannot assume warranty for possible modifications on the part of the cable manufacturer. It is the user’s responsibility to ensure the compatibility of the chosen components and their appropriateness for the intended application.

03/2023

Downloads

Poles / Product Inquiry

Designation Poles PU
(pieces)
MDQ
(pieces)
RFQ
(pieces)
Request for quote
(notes)
3625 0117,2007,200

Product Inquiry

Branch
Name / Company
Address
Contact