36 3648
RAST 5 connectors, pitch 5.0 mm

RAST 5 chassis tab header, insulation displacement technology (IDT)
批准 VDE, cULus
技术数据
环境条件
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
物料
Insulating body: PA, V-2 according to UL94 *1
Contact tab: CuSn, tin-plated
1) component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
IDT区域可连接的导线
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 0,5 mm²
Section max.: 0,82 mm²
Insulation diameter: ≤ 2,5 mm
电气数据(Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 6 A (0.75 mm², Tamb 90 °C)
10 A (0.75 mm², Tamb 60 °C)
Rated voltage: 250 V AC
配对件

3623 01 V01
RAST 5 connector for indirect mating, insulation displacement technology (IDT), with locking on tab, consecutive placement without loss of pitch

3623
RAST 5 connector for indirect mating, insulation displacement technology (IDT), with exterior lock, consecutive placement without loss of pitch

3626
RAST 5 connector for indirect mating, insulation displacement technology (IDT), with interior locking, consecutive placement without loss of pitch

3611
RAST 5 connector for indirect mating, with screw terminal, with lift clamp with protection against misplacing, with interior locking, consecutive placement without loss of pitch

3615
RAST 5 connector for indirect mating, with screw terminal, with lift clamp with protection against misplacing, with test holes and interior locking, consecutive placement without loss of pitch, cable departure opposite to lock

3615-1
RAST 5 connector for indirect mating, with screw terminal, with lift clamp with protection against misplacing, with test holes and interior locking, consecutive placement without loss of pitch, cable departure opposite to lock, with handle latch

3615-2
RAST 5 connector for indirect mating, with screw terminal, with lift clamp with protection against misplacing, with test holes and interior locking, consecutive placement without loss of pitch, cable departure on side of lock

3615-3
RAST 5 connector for indirect mating, with screw terminal, with lift clamp with protection against misplacing, with test holes and interior locking, consecutive placement without loss of pitch, cable departure on side of lock, with handle latch
线束组装设备
批准的电线
批准的电线,用于 3648 Download (PDF)
导体 | 绝缘 | 制造商 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Typ | 截面积 (mm²) |
结构 | 绞距 (mm) |
表面处理 | 直径 (mm) |
材料 | 温度范围 (°C) |
名称 | 名称 | 描述 |
3648 | 0,5 | 19 x Ø 0,19 mm | 17 | - | 1,8 ± 0,1 | PVC | +105 | Alstermo | 1428 | |
3648 | 0,5 | 19 x Ø 0,18 mm | 20 | - | 2,15 ± 0,1 | PVC | +70 | Salcavi | R15732 | |
3648 | 0,5 | 19 x Ø 0,182 mm | 22 | - | 2,1 ± 0,05 | PVC lead-free | +70 | Leoni, Poland | 60200500K | H05V-K 1x0,5 mm² BL SKT |
3648 | 0,5 | 19 x Ø 0,180 mm | 22 | - | 2.1 | PVC | -5/+70 | Leoni | 60200500Z | H05V-K 1x0,5 BL |
3648 | 0,5 | 16 x Ø 0,21 mm | 22 | Sn | 2,2 ± 0,1 | PVC lead-free | +90 | Leoni | 60200820M | H05V-K1x0,5V ZSKT90C-FBG |
3648 | 0,5 | 16 x Ø 0,194 mm | 22 | Sn | 2,1 ± 0,1 | PVC | +90 | Leoni | 60200825M | |
3648 | 0,5 | 16 x Ø 0,195 mm | 44 | - | 2,1 ± 0,1 | PVC | +90 | Leoni | 60780080A | H05V-K 1x0,50mm² 90°C |
3648 | 0,5 | 19 x Ø 0,182 mm | 22 | - | 2,1 ± 0,1 | PVC | +90 | KWL | 641105.96 | |
3648 | 0,5 | 19 x Ø 0,18 mm | 20 | - | 2,15 ± 0,1 | PVC | +70 | Salcavi | R15731 | H05V-K 0,50mm2 |
3648 | 0,5 | 19 x Ø 0,18 mm | 20 | - | 2,15 ± 0,1 | PVC | +70 | Salcavi | R15733 | |
3648 | 0,5 | 19 x Ø 0,182 mm | 22 | - | 2,1 ± 0,1 | PVC | +90 | Leoni | 60170060Z | H05V2-K 1x0,5 mm² BL SKT |
3648 | 0,5 | 19 x Ø 0,18 mm | 20 | - | 2,15 ± 0,1 | PVC | +70 | Salcavi | R15734 | |
3648 | 0,5 | 16 x Ø 0,193 mm | 18 | - | 2,3 ± 0,1 | PVC | +70 | Salcavi | R45366 | |
3648 | 0,5 | 16 x Ø 0,193 mm | 18 | - | 2,3 ± 0,1 | PVC | +70 | Salcavi | R45367 | H03VV-F 2 x 0,50 mm² |
3648 | 0,5 | 19 x Ø 0,18 mm | 20 | - | 2,08 ± 0,1 | PVC | +90 | Salcavi | R45383 | H03V2V2-F 3x0,50 mm2 |
3648 | 0,5 | 16 x Ø 0,180 mm | 36 | - | 1,88 ± 0,1 | PVC | +70 | Salcavi | R45444 | |
3648 | 0,5 | 16 x Ø 0,21 mm | 28 | Sn | 2,20 + 0,05/-0,10 | TPS-SBS | -40/+125 | KBE | 5200500010190Z | LI31Y 0,50 mm² |
3648 | 0,5 | 16 x Ø 0,21 mm | < 45 | - | 1,55 ± 0,05 | PVC | -40/+105 | C.E.CAM. | HT050IN23 | 0.5 |
3648 | 0,5 | 19 x Ø 0,19 mm | 27 | - | 1,60 -0,20 | PVC | -40/+105 | Leoni | 76783021# | FLRY 0,5-A |
3648 | 0,5 | 7 x Ø 0,30 mm | 23 | Sn | 2 ± 0,3 | PVC | +90 | Leoni | 60171100A | |
3648 | 0,5 | 19 x Ø 0,182 mm | 18 | - | 2,1 ± 0,05 | PVC lead-free | +70 | Leoni, Turkey | 60200610K | H05V-K 1x0,5 mm² BL SKT |
3648 | 0,5 | 19 x Ø 0,194 mm | 22,5 | Sn | 2,05 ± 0,05 | PVC lead-free | +105 | KBE | 4100201110194K | UL 20 AWG AWM Style 1569 |
3648 | 0,5 | 16 x Ø 0,21 mm | 28 | Sn | 2,3 ± 0,2 | PVC | +70 | KBE | 3300500010190E | H05V - K0,50 mm² |
3648 | 0,5 | 16 x Ø 0,19 mm | 21,7 | - | 1,81 | PVC | +105 | Pirelli, Turkey | 88746 | 03V2V2-F 6G0,50 |
3648 | 0,5 | 16 x Ø 0,19 mm | 21,7 | Sn | 2,01 | PVC | +105 | Pirelli, Turkey | 89483 | 05V2V2-F 3G0,50 |
3648 | 0,5 | 7 x Ø 0,30 mm | 20 | Sn | 2,12 | PVC | +90 | Alcatel | 478323 | |
3648 | 0,5 | 7 x Ø 0,31 mm | 25 | Sn | 1,85 ± 0,1 | PVC | +105 | Coroplast | 10-7208 | |
3648 | 0,5 | 16 x Ø 0,20 mm | 17 | - | 2,20 ± 0,05 | PVC | +105 | Jiangyang | 9000162432 | RV 1X0,5 mm² |
3648 | 0,5 | 16 x Ø 0,19 mm | 25 | - | 1,7 | PVC | +90 | Nexans | 13094900116 | SKK 5G0,5 mm² |
3648 | 0,5 | 16 x Ø 0,20 mm | 22 | - | 2,10 ± 0,30 | PVC lead-free | +70 | Prysmian, Turkey | 2006-VS-70-050 | H05V-K 0.50 mm² |
3648 | 0,5 | 19 x Ø 0,182 mm ± 0,005 | 23 | - | 1.1 | PVC | -15/+90 | KBE | 3100500020185T | H05V2-K 0,50 mm² |
3648 | 0,5 | 16 x Ø 0,20 mm | 33 ± 5 | - | 1,85 | PVC | -30/+70 | Vrchlabí | DP59004161 | Schlauchleitung H03 VV-F 3G0,5 |
3648 | 0,5 | 7 x Ø 0,30 mm | 23 | Sn | 2,2 ± 0,2 | PVC | +90 | KBE | 3500500010300T | |
3648 | 0,5 | 7 x Ø 0,30 mm | 25 | - | 2,1 ± 0,1 | PVC lead-free | +90 | Coroplast | 4-0551 | H05V2-R 0,50 mm² blank SKT |
3648 | 0,5 | 7 x Ø 0,30 mm | 17,5 | Sn | 2,1 ± 0,2 | PVC | +70 | KBE | 3300500010300E | H05V-U 0,50 mm2 |
3648 | 0,56 | 7 x Ø 0,32 mm | 15 | Sn | 1,75 ± 0,05 | PVC | +105 | Leoni | 89170490A | |
3648 | 0,56 | 19 x Ø 0,194 mm | 22 | Sn | 2,05 ± 0,05 | PVC lead-free | +105 | Leoni, Mexico | 89170822G | LIYW 0,56 Sn AWG 20/19 UL1569 CSA T1 |
3648 | 0,56 | 19 x Ø 0,194 mm | 22 | Sn | 2,05 ± 0,05 | PVC lead-free | +105 | Leoni | 89170822A | LIYW 0,56 Sn AWG 20/19 UL1569 CSA T1 |
3648 | 0,56 | 19 x Ø 0,194 mm ± 0,006 | 22 | - | 2,05 ± 0,05 | PVC | -30/+90 | Leoni | 89170820A | LiYW 0,56 BL AWG 20/19 |
3648 | 0,61 | 19 x Ø 0,203 mm | 13 ± 2,0 | Sn | 1,29 ± 0,05 | ETFE | -65/+150 | TangYao | MIL-W-22759/ 18-20, brown | AWG 20, brown |
3648 | 0,62 | 19 x Ø 0,203 mm | 13 ± 2 | Sn | 1,52 ± 0,05 | ETFE | -65/+150 | TangYao | MIL-W-22759/ 16-20, green/yellow | AWG 20, green/ yellow |
3648 | 0,75 | 24 x Ø 0,2 | 35 | - | 2,3 ± 0,1 | PVC | -5/+90 | Helukabel | 83661 | H05VV5-F, AWG19 |
3648 | 0,75 | 23 x Ø 0,20 mm | 27 | - | 2,20 ± 0,20 | PVC lead-free | +70 | Prysmian, Turkey | 2006-VS-70-075 | H05V-K 0.75 mm² |
3648 | 0,75 | 24 x Ø 0,20 mm | 16 | - | 2,3 | PVC | +90 | Nexans | 47411819 | |
3648 | 0,75 | 24 x Ø 0,20 mm | 44 | Sn | 2,4 ± 0,2 | Silicone | +180 | Cet | 550719230 | K/FG4/2 (CuR) - K/SIF (CuS) |
3648 | 0,75 | 7 x Ø 0,366 mm | 22 | - | 2,35 + 0,1 | PVC | +90 | Leoni | 60165020A | |
3648 | 0,75 | 24 x Ø 0,194 mm | 15 | Sn | 2,3 ± 0,1 | PVC | +90 | Leoni | 60100052M | H05V-K1x0, 7524SNSKT90C2-FBG-3S |
3648 | 0,75 | 22 x Ø 0,21 mm | 35 | - | 2,35 + 0,1 | PVC | +90 | Coroplast | 4-0600 (0,75)-A2 | H05V2-K 0,75mm² |
3648 | 0,75 | 24 x Ø 0,20 mm | 16,5/17 | - | 2,40 ± 0,05 | PVC | +105 | Jiangyang | 9000162434 | RV 1x0,75 mm2 |
3648 | 0,75 | 22 x Ø 0,20 mm | 35 | - | 2,3 ± 0,1 | PVC | +90 | Coroplast | 5-1732 | (N)YMHYW-J |
3648 | 0,75 | 24 x Ø 0,194 mm ± 0,006 | 22 ± 2,2 | - | 2,35 ± 0,05 | PVC | -40/+90 | Leoni | 60170024M | H05V2-K 0,75 mm² |
3648 | 0,75 | 24 x Ø 0,194 mm | 22 | - | 2,4 ± 0,1 | PVC lead-free | +70 | Leoni, Poland | 60200517S | H05V-K 1x0,75 mm² BL SKT |
3648 | 0,75 | 24 x Ø 0,195 mm | 30 | - | 2,15 | PVC | +70 | Krania | QM-5-560 | |
3648 | 0,75 | 24 x Ø 0,193 mm | 55 | - | 1,75 ± 0,05 | PVC lead-free | +105 | Condumax | DIN 72551-6 | FLRY-B 300V 0,75 mm2 |
3648 | 0,75 | 7 x Ø 0,37 mm | 18 | - | 2,4 | PVC | +70 | Leoni | 68256 | H05V R 0,75 mm² |
3648 | 0,75 | 24 x Ø 0,194 mm | 22 | - | 2,05 ± 0,05 | PVC lead-free | +105 | Leoni | 89171520A | LIYW 0,75 BL AWG 19/24UL 1569 CSA T1 |
3648 | 0,75 | 7 x Ø 0,37 mm | 16,9 | - | 2,4 ± 0,1 | PVC | +70 | Profiplast | 5007901090F | |
3648 | 0,75 | 7 x Ø 0,37 mm | 18 | Sn | 2,35 + 0,1 | PVC | +90 | Leoni | 88221160B | |
3648 | 0,75 | 16 x Ø 0,254 mm | 20 | - | 2,05 ± 0,05 | PVC | +105 | Quinro | 7-238 | WIRE UL 1569 AWG 18 300V 105°C |
3648 | 0,75 | 24 x Ø 0,194 mm | 22 | - | 2,4 ± 0,1 | PVC | +90 | KWL | 641106.96 | |
3648 | 0,75 | 23 x Ø 0,20 mm | 27 | - | 2,20 ± 0,20 | PVC lead-free | +90 | Prysmian, Turkey | 2006-VS-90-075 | H05V2-K 0.75 mm² |
3648 | 0,75 | 24 x Ø 0,194 mm | 22 | - | 2,35 ± 0,05 | PVC | +90 | KBE | 3100750020198T | H05V2-K 0,75mm² |
3648 | 0,75 | 24 x Ø 0,194 mm | 22 | - | 2,4 ± 0,1 | PVC lead-free | +70 | Leoni, Poland | 60200512M | H05V-K 1x0,75 mm² BL SKT |
3648 | 0,75 | 24 x Ø 0,194 mm | 28 | - | 2,05 ± 0,05 | PVC lead-free | +105 | Leoni, Mexico | 89860040A | |
3648 | 0,82 | 16 x Ø 0,254 mm | 20 | Sn | 2 ± 0,05 | PVC | +105 | Leoni | 89460140A | LiYW 0,82 SN AWG 18/16 SKT UL 1569 +CSA T1 |
3648 | 0,82 | 16 x Ø 0,254 mm | 20 | - | 2,05 ± 0,05 | PVC lead-free | +105 | Leoni | 89170515A | LIYW 0,82 BL AWG 18/16 UL 1569 CSA T1 |
3648 | 0,82 | 16 x Ø 0,254 mm | 22 | Sn | 2 ± 0,1 | PVC | +105 | Leoni | 83023155A | LIYYW 2x0,82 AWG 20/16 UL2517 |